Ac SPD Key Features
1. High Surge Protection Capacity
Engineered to protect electrical systems from high-voltage spikes and lightning strikes.
● Handles nominal discharge currents of 40kA, 60kA, or 80kA.
● Maximum discharge current of 40kA or 60kA for ultimate reliability.
2. Wide Compatibility
Ac SPD is designed for versatile use across various power supply systems.
● Compatible with TT, IT, TN-S, TN-C, and TN-C-S systems.
● Supports power systems up to 230/400V AC, 50/60Hz.
3. Advanced Safety Standards
Surge Protection Device is Certified and built to meet global quality and safety requirements.
● Meets IEC/EN 61643-1 standards for surge protection.
● CE-certified for dependable performance in critical applications.
4. Easy Installation and Maintenance
It conveniently fits into standard low-voltage distribution boxes for quick deployment.
● Compact design suitable for building incoming line setups.
● Capable of discharging up to 100 kA of lightning current.
Specifications
● Type: YCS6-C
● Poles: 4 Pole
● Nominal Discharge Current (In): 20KA, 30KA
● Maximum Discharge Current (Imax): 40kA, 60kA, 80KA
● Continuous Operating Voltage (Uc): 385V
● Standard: IEC/EN 61643-1
● Certificate: CE
General
● Suitable for low-voltage AC systems with up to 230/400V, 50/60Hz.
● Designed for installation in incoming line distribution boxes in buildings.
● Protects electrical systems by discharging up to 100 kA lightning currents.
● Ensures safety and reliability across various electrical configurations.
Rated Operating Voltage Uc (V~) |
380V |
Maximum Continuous Operating Voltage Uc (V~) |
385V, 420V, 440V |
Voltage Protection Level Up (V~) kV |
≤1.5 |
Nominal Discharge Current In (8/20µs) kA |
25 |
Maximum Discharge Current Imax (8/20µs) kA |
30 |
Response Time ns |
<25 |
Test Standard |
IEC61643-1 |
L/N (mm²) The Cross Section of L/N Line |
2.5 |
PE (mm²) The Cross Section of the PE Line |
6 |
Fuse or Switch (A) |
25A, 32A |
Operating Environment (°C) |
-40°C to +85°C |
Relative Humidity (25°C) |
≤95% |
Installation |
Standard Rail 35mm |
The AC Surge Protection Device (SPD) Installation
When installing your AC Surge Protection Device (SPD), remember to follow these critical procedures for optimal performance and safety:
1. Mounting Locations:
The primary electrical panel or distribution board is the proper place to mount the SPD on a 35 mm standard rail.
Step 2:
Hook up the SPD to the AC power line in series. Be sure to securely attach the Line (L), Neutral (N), and Protective Earth (PE) wires to their respective SPD terminals.
3. Sufficient grounding: For the SPD to function correctly and safely, it must have sufficient grounding. The PE (Protective Earth) connection needs to have a large enough cross-sectional area to withstand any surges that may occur.
The gadget can function in environments with temperatures ranging from -40°C to +85°C, according to the fourth environmental condition. When installing, ensure the area is at the ideal temperature and humidity for optimal operation.
AC SPD Cartridge That Can Be Taken Out
The part of the AC SPD that makes it easier to use and keep up is the cartridge that can be taken out and put back in.
1. Easy to Change:
You can change the cartridge in the SPD without having to disconnect the whole system or do a lot of difficult wiring.
You won't have to wait long when the cartridge needs to be changed, thanks to this feature.
Change Indicator:
The machine may have a feature that lets you know when the cartridge needs to be changed. Most of the time, this is because the cartridge was taken in a rush. This is a safety measure to keep the electricity system safe.