Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
+92-300-7888272
info@c-power.pk
Couldn't load pickup availability
KUKA’s H1Z2Z2-K Solar Cables (available in 4mm² and 6mm² variants) are high-performance, TÜV-certified cables designed for photovoltaic systems. Engineered for durability, safety, and long-term efficiency, these cables are ideal for interconnecting solar panels and other components in PV installations.
Voltage Rating: 1500V DC (TÜV), 1.5/1.5kV DC, 1.0/1.0kV AC
Standards: TÜV EN50618 H1Z2Z2-K | IEC62930
Conductor: Flexible tinned copper (Class 5)
4mm²: 56 strands of 0.285mm | Diameter: 2.6mm ± 0.04mm
6mm²: 84 strands of 0.285mm | Diameter: 3.0mm ± 0.04mm
Insulation & Jacket: XLPO, electron-beam cross-linked, halogen-free, low smoke (LSHF)
Jacket Colors: Black or Red
Outer Diameter:
4mm²: 5.6mm ± 0.2mm
6mm²: 6.1mm ± 0.2mm
Temperature Range: -40°C to +90°C (Max conductor temp: +120°C)
Short Circuit Temperature: 250°C for 5s
UV & Ozone Resistance: Complies with EN 50289-4-17 and EN 50396
Halogen Free & Flame Retardant: EN 60754-1 | EN 60332-1-2
Minimum Bending Radius: Fixed: 4×OD | Flexing: 5×OD
Service Life: 30 years (anticipated)
Conductor Resistance (at 20°C):
4mm²: ≤ 5.09 Ω/km
6mm²: ≤ 3.39 Ω/km
Insulation Resistance:
4mm²: ≥ 580 MΩ·km
6mm²: ≥ 1000 MΩ·km
Test Voltage: AC 6.5kV for 5 min | Spark Test: AC 10kV
Installation Condition |
4mm² (A) |
6mm² (A) |
Exposed |
55 |
70 |
On Surface (No Contact) |
52 |
67 |
On Surface (With Contact) |
44 |
57 |
In Conduit / Pipe / Duct |
33 |
44 |