Type:YCB9ZF-100W Rated current:63A,100A
Poles:4P Short circuit breaking capacity:6kA
Mechanical life:More than 20000 times
Electrical life:More than 6000 times
Operating environment temperature:40 ℃~70 ℃
The General features of this system include data monitoring, fault alarm, and protection, as well as centralized management.
It also enables for the analysis of energy use, making it more efficient. The system is equipped with a portable barrier remover to help in emergencies, and it can handle dangerous situations at any time and from anywhere.
The system provides remote control, rights management, regional searches, and data reporting generating capability.
Additionally, it provides remote location diagnosis for easier troubleshooting.
Features:
Early warning, fault location, fault alarm, and tripping protection define the system.
It guarantees defense from overvoltage, undervoltage, overload, and over temperature. The system also protects against voltage/current imbalance and fault phase protection.
The system offers choices for maintenance and overhauls so as to guarantee safety and stop electricity theft.
There are custom warning thresholds for short circuit protection and power contrast.
Additionally, the system provides troubleshooting advice, fault case recording, and conditional linkage control.
In terms of Features, this system comprehensively protects the safety of human electricity, offering both local and remote integrated control along with remote leakage self-check.
Easy checkability of the operating record guarantees electrical fire monitoring. Early warning, fault location, fault alarm, and tripping protection define the system.
It guarantees defense from overvoltage, undervoltage, overload, and over temperature. The system also protects against voltage/current imbalance and fault phase protection.
The system offers choices for maintenance and overhauls so as to guarantee safety and stop electricity theft.
There are custom warning thresholds for short circuit protection and power contrast. Additionally, the system provides troubleshooting advice, fault case recording, and conditional linkage control.
Item |
YC89ZF-100W(WIFI) |
Product |
4 pole Wifi Breaker |
Rated voltage |
Single-phase AC230V, 50/60Hz |
Rated current |
100A |
Residual operating current |
30-300mA |
Short-circuit breaking capacity |
Icn=Ics=6kA |
Mechanical life |
More than 20,000 times |
Electrical life |
More than 3,000 times |
Acting time |
Leakage action less than 130ms; Closing time is less than 1.5s and opening time is less than 5s |
Protection grade |
IP20 |
Operating environment temperature |
-40°C to +70°C |
Item |
Data |
Thermo-magnetic release characteristic |
C type (Other types can be customized) |
Rated current In |
32A, 40A, 63A, 80A, 100A |
Rated short-circuit capacity Icn |
6kA |
Short-circuit protection |
When there is short circuit fault, it can trip within 100ms |
Over and under voltage protection |
When there is over or under voltage fault, it can trip after 3s (0~99s can be set); Percentage can be set for over and under voltage |
Overload delay protection |
According to rated current, meet standard IEC 60898-1 requirement |
Timing control |
Set according to requirements |
Check |
The voltage and switching status can be checked through the APP on the phone |
Manual automatic integrated control |
Mobile phone APP control, can also be controlled through the handle |
Communication mode |
Wireless WIFI |
Under abnormal voltage leakage: Product IP20 YCB9ZF-100W(WIFI) If the device is in the state of breaking, the device will not close automatically, but can only close remotely by controlling the device end or manually by local operation.
If the device is in the closing state, the device will not open automatically, but can only close remotely by controlling the device end or manually open by the device requires local manual operation.
If the equipment is in the closing state, the equipment will automatically open, and voltage is changed to normal.
If the leakage self-check is not normal, the equipment will continue to open automatically once.
After troubleshooting, manually operate locally or remotely control the closing. If the device is in the opening state at this time, the device will not close automatically. After the voltage returns to normal, the device needs to be manually and locally operated or remotely controlled to close
Users can remotely monitor and control the Wi-Fi breaker by connecting it to the Tuya Smart App. The software allows users to remotely turn on or off the breaker, monitor energy usage, and receive real-time status updates.
The Tuya Smart App enhances convenience and provides intelligent control through basic remote capabilities, allowing users to schedule tasks, automate processes, and ensure system security.