Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
Free Shipping on Orders Above 10,000 |
Orders placed under the Cash on Delivery (COD) payment method will be delivered within 3 to 4 working days. |
Available for same-day delivery in Lahore for orders placed before 4:00 PM. |
Welcome to the Official CNC Electric Store |
+92-300-7888272
info@c-power.pk
Couldn't load pickup availability
Seiko design, Cloud control, GPRS connection, small volume, High breaking
ability, flameresistant material, Energy conservation and environment
protection,International standard, All-round service.
● Data monitoring
● Fault alarm, protection
● Centralized management
● Analysis of energy consumption
● Portable barrier remover
● Handle dangerous situations anytime and anywhere
● Remote control
● Rights management
● The regional search
● Data report
● Remote location + diagnosis
Comprehensively protect the safety of human electricity
● Local + remote integrated control Local + remote leakage self-check
● Operation record can be checked
● Electrical fire factor monitoring
● Fault early warning
● Fault location/fault alarm
● Tripping protection
● Over undervoltage protection
● Overload protection
● Over temperature protection
● Open phase protection
● Voltage/current imbalance
● Fault phase protection
● Preventing electricity-stolen
● Maintenance and overhauls closed by mistake
● Current limit
● Scene mode
● Line timing
● Rights management
● Automatic reclosing
● Generate report analysis automatically
● Local + remote locking
● The leakage protection current can be adjusted
● Custom warning thresholds
● Short circuit protection
● Power contrast
● Troubleshooting advice
● Fault cause recording
● Conditional linkage control
● Centralized management
● Power factor calculation
● Historical data import
● Electricity statistics
● Chart simulation display
● Status indication
The Changeover Switch can switch on,Load and break the circuit under normal
conditions,using as Switch Disconnectors.
Standard: IEC 60947-5-1
● OLED lattice LIQUID crystal display has long life and good low temperature
characteristics;
● Can be set as a communication gateway, through the ontology 485 interface for
the branch small current switch combination networking;
● It integrates multiple protection functions such as over voltage, under voltage,
missing phase, wrong phase, loss of voltage, overload, short circuit, leakage,
temperature, voltage/current imbalance, over power, under power, anti-power
theft and so on into one, and supports early warning in accordance with the preset
proportion;
● Multiple functions can be closed, alarm, trip any combination, more widely
applicable;
● Support 12 months frozen electric energy and 7 days frozen electric energy query,
let the remote energy management more convenient;
● Electric parameters such as active power, reactive power, apparent power and
power factor are supported for collection and uploading;
● Support positive and negative energy statistics.
● RS485 in non-gateway mode supports DL/T-645/Modbus protocol and automatic
conversion;
● Support external dry contact control, cabinet door control;
● Support multiple groups of any time timer control closing, opening operation, so
that the control more arbitrary;
● Multi-component modular design, optional collocation, more flexible use
● Remote wireless communication technology, supporting 2G, 4G, Ethernet, wifi,
Bluetooth,MQTT and other communication modes;
● Operation event alarm event failure event real-time reporting, so that you can
know your equipment running state anytime and anywhere; The alarm can be
accompanied by a buzzer prompt, and can be muted remotely or locally, making
the device alarm more intelligent;
● Support a variety of remote OTA upgrade mode, so that equipment upgrade
maintenance no longer trouble;
● Hundreds of local event records (power on, power off) are stored, which can be
checked at any time for accident cause analysis;
● The clock is timed and synchronized on the cloud to ensure the accuracy of event
recording time. The daily error is no more than 1S in the case of no network;
● Real-time statistics of the number of events can focus on frequent abnormal,
support switching display in Chinese and English;
● Support 12 months frozen electric energy and 7 days frozen electric energy query, let the remote energy management moreconvenient;
● Electric parameters such as active power, reactive power, apparent power and power factor are supported for collection and uploading;
● Support positive and negative energy statistics.
Item |
Data |
Thermo-magnetic release characteristic |
C type (Other types can be customized) |
Rated current (In) |
63A / 100A |
Rated short circuit capacity Icn |
10kA |
Short circuit protection |
When there is a short circuit fault, it can trip within 100ms |
Leakage protection |
When there is a leakage fault, it can trip within 100ms |
Leakage protection value |
30mA (customizable) |
Over-voltage protection |
According to the set value, the trip time: hard cut-off: 1s |
Under-voltage protection |
According to the set value, the trip time: hard cut-off: 1s |
Over and under voltage protection setting |
When voltage is over 275–300V or under 165–180V, can be set |
Off-delay setting |
0–99s, can be set |
Overload protection |
1–63A can be set, Off-delay time 0–99s can be set |
Over-current protection |
D–10*C current can be set, Off-delay time 0–99s can be set |
Over power protection |
The amount of load change can be set, Off-delay time 0–99s can be set |
Under power protection |
The amount of load change can be set, Off-delay time 0–99s can be set |
Phase loss protection |
Can be set |
Phase sequence protection |
Can be set |
Delay on power restoration |
0–300s can be set |
Operation times |
Record times of circuit breaker operations |
Display |
LCD screen displays total current, real-time, overload, short circuit, leakage, etc. |
Check |
Test buttons and fault recall buttons are available |
Communication protocol |
Standard Modbus protocol (optional RS485, WiFi, Zigbee, 4G) |
Remote control |
Can be switched on/off by remote control (e.g. app, software) |
Remote fault alarm |
Fault information pushed to system (overload, leakage, etc.) |
Cloud data storage |
Circuit breaker operation record uploaded to cloud, real-time access |
Firmware upgrades |
Remote upgrade available |
Customizable modules and functions |
Modular combination and expansion; supports metering, temperature, smoke, arc detection, power limiting, surge protection, timing control, programmable scenes, etc. |
The following functions can be set: |
Open, close, alarm, jump-to-scene, etc. |
Can be set to support overvoltage, undervoltage, overcurrent, overload, leakage, short circuit, phase loss, phase sequence, temperature, smoke, arc, power limit, energy metering, surge protection, timing, programmable scenes |